Coating Thickness Gauge PTG-3500 | | |
Product Overview:PHASE ‖ PTG-3500 Series thickness using eddy current and magnetic induction principle to be completed by the thickness measurement of two ways. Two non-destructive measurement methods are very accurate. Unmatched by the two arbitrary thickness, you can easily use the built-in sensor type or sensor type to detect external magnetic substrates (iron based) or non-magnetic coatings on non-magnetic matrix (non-iron based) on the insulator.
PHASE ‖ PTG-3500 suitable for many industrial fields such as manufacturing, general engineering, chemical inspection.
PTG-3500 with built-in sensor-based automatic identification of iron or non-iron base and is equipped with two substrate samples (steel, aluminum), 4 the thickness of the calibration test block, equipment boxes, batteries and operating manual. |
The main parameters:
●Measuring range:0-1000um or 0-40Mils
●Resolution: 0.1um/0.01mils (0-99um) or 1mm (over 100um)
●Ensure tolerance: a little after calibration = / -1-3% n or 2Um
●Display: 4 digits
●Minimum measuring area: 5mm * 5mm
●Minimum curvature: convex 0.12 "(3mm) concave: 1.2" (30mm) |
●Minimum substrate thickness:
●Fe-based:20mils(0.5mm)
●Non-Ferrous:2mils(50mm)
●Calibration: zero calibration / calibration foil
●The north side of the surface maximum temperature: 302 degrees Fahrenheit (150 degrees C)
●Longest contact time: 2 seconds
●Power supply: 4 AAA batteries
●Size:161*69*32mm
●Weight:260g |